Personal tools

Sponsorname

Your company could advertise here

www.fla-consulting.eu

Reference:GBR MEDDEV 2.7/3 revision 3 May-2015 8: Difference between revisions

From GxPlex

Jump to: navigation, search
m 1 revision imported
imported>GxPlexBot
Import from GxPlex Excel
Line 4: Line 4:
|RefDocPart=8
|RefDocPart=8
|RefLanguage=EN
|RefLanguage=EN
|RefTagsEN=
|RefTags=TAG-00066-Cau-enh ++ TAG-00155-Med-Med ++ TAG-00045-Adv-hte ++ TAG-00261-Una-ner
|RefTagsOriginal=
|RefModule=5
|RefTagsFR=
|RefUnit=5.1.3
}}
}}


Line 14: Line 14:
|-
|-
! colspan="2" class="gplx-infobox-header" | Reference Details
! colspan="2" class="gplx-infobox-header" | Reference Details
|-
! Module
| Module 5 — Unit 5.1.3
|-
|-
! Scope
! Scope
Line 30: Line 33:
|  
|  
|-
|-
! Tags (EN)
! Tags
|  
| [[Glossary:TAG-00066-Cau-enh|Causality]], [[Glossary:TAG-00155-Med-Med|Medical device]], [[Glossary:TAG-00045-Adv-hte|Adverse event]], [[Glossary:TAG-00261-Una-ner|Unanticipated device effect]]
|-
! Tags (original language)
|  
|-
! Tags (FR)
|  
|-
|-
! Comment
! Comment

Revision as of 17:29, 15 July 2026



Document information
Reference GBR MEDDEV 2.7/3 revision 3 May-2015
Validity area GBR
Scope(s) MD
Document name MEDDEV 2.7/3 revision 3
Version / Revision May-2015
Status Current
Document type Official guideline
Language(s) EN
Description GUIDELINES ON MEDICAL DEVICES CLINICAL INVESTIGATIONS:

SERIOUS ADVERSE EVENT REPORTING UNDER DIRECTIVES 90/385/EEC AND 93/42/EEC.

Official source Official link
Restricted access No
Submitted by Florian Adragna
Contributors


Reference Details
Module Module 5 — Unit 5.1.3
Scope MD
Document part 8
Language EN
Original entry by Florian Adragna
Contributors
Tags Causality, Medical device, Adverse event, Unanticipated device effect
Comment Causality assessment for device-related adverse events

Content

8. CAUSALITY ASSESSMENT The relationship between the use of the medical device (including the medical - surgical procedure) and the occurrence of each adverse event shall be assessed and categorized. During causality assessment activity, clinical judgement shall be used and the relevant documents, such as the Investigator’s Brochure, the Clinical Protocol or the risk Analysis Report shall be consulted, as all the foreseeable serious adverse events and the potential risks are listed and assessed there. The presence of confounding factors, such as concomitant medication/treatment, the natural history of the underlying disease, other concurrent illness or risk factors shall also be considered. The above considerations apply also to the serious adverse events occurring in the comparison group. For the purpose of harmonising reports, each SAE will be classified according to five different levels of causality. The sponsor and the investigators will use the following definitions to assess the relationship of the serious adverse event to the investigational medical device or procedures.

1) Not related [...]

2) Unlikely: [...]

3) Possible [...]

4) Probable [...]

5) Causal relationship [...]

The sponsor and the investigators will distinguish between the serious adverse events related to the investigational device and those related to the procedures (any procedure specific to the clinical investigation). An adverse event can be related both to procedures and the investigational device. Complications of procedures are considered not related if the said procedures would have been applied to the patients also in the absence of investigational device use/application. In some particular cases the event may be not adequately assessed because information is insufficient or contradictory and/or the data cannot be verified or supplemented. The sponsor and the Investigators will make the maximum effort to define and categorize the event and avoid these situations. Where the sponsor remains uncertain about classifying the serious event, it should not exclude the relatedness and classify the event as “possible”. Particular attention shall be given to the causality evaluation of unanticipated serious adverse (device) events. The occurrence of unanticipated events related to the use of the device (USADE) could suggest that the clinical investigation places subjects at increased risk of harm than was to be expected beforehand.