Personal tools

Sponsorname

Your company could advertise here

www.fla-consulting.eu

Reference:ICH ICH E6 Guideline R3 (2025) III. Annex 1 3.11.4.5.3

From GxPlex

Revision as of 15:27, 29 June 2026 by gxplex>GxPlexBot (Import from GxPlex Excel)
Jump to: navigation, search



Document information
Reference ICH ICH E6 Guideline R3 (2025)
Validity area ICH
Scope(s) HM
Document name ICH E6 Guideline
Version / Revision R3 (2025)
Status Current
Document type International guideline
Language(s) EN
Description GUIDELINE FOR GOOD CLINICAL PRACTICE
Official source Official link
Restricted access No
Submitted by Florian Adragna
Contributors


Reference Details
Scope G
Document part III. Annex 1

3.11.4.5.3

Language EN
Original entry by Florian Adragna
Contributors
Tags (EN)
Tags (original language)
Tags (FR)
Comment Monitoring of investigational product management

Content

3.11.4.5.3 Monitoring of Investigational Product Management (a) Confirming, for the investigational product(s):

  (i) That storage conditions are acceptable and in accordance with the storage requirements specified in the protocol or other relevant documents;
  (ii) That supplies are sufficient throughout the trial and are used within their shelf life;
  (iii) That the correct investigational product(s) are supplied only to participants who are eligible to receive it at the protocol-specified dose(s) and, where appropriate, in accordance with the randomisation procedures;
  (iv) That the participants, investigator, investigator site staff and other relevant parties and individuals involved in the trial conduct are provided with necessary instruction on properly storing, using, handling, returning and destroying, or alternative disposition of the investigational product(s);
  (v) That the receipt, storage, use, handling, return and destruction or alternative disposition of the investigational product(s) are controlled and documented adequately;
  (vi) That the disposition of unused investigational product(s) complies with applicable regulatory requirement(s) and is in accordance with the sponsor requirements;
  (vii) Where product available on the market is dispensed and used in accordance with applicable regulatory requirements, some of the previously outlined considerations may not be applicable.